EN RU ET
About us Water Treatment Chemical Deaeration Dispatching & Automation Digital solutions Contact
Industrial Technologies · Estonia, EU

Chemical Water Treatment
& Smart Dispatching

Two core services — protecting boilers and heat networks from corrosion and scale, and automating their remote SCADA/PLC monitoring and control.

IMWTP
Certified
SCADA
Remote
PLC
Automation
EU
Estonia
💧 Chemical Water Treatment 📡 Dispatching & Automation
Neiron Technology OÜ — Estonian engineering company logo
Neiron Technology OÜ
Tallinn, Estonia · EU Company
Registry code17122902
VATEE102900668
Registered27.11.2024
AddressJ. Koorti tn 2-33, 13623
Tallinn, Estonia
Phone+372 5403 2172
Emailneiron.technology@gmail.com
DirectorPavlo Laksa
About the company

Two directions — one trusted partner

Neiron Technology OÜ is an Estonian engineering company with two core service areas: chemical water treatment for industrial thermal systems, and automated dispatching & remote monitoring for boiler rooms and heat networks.

Registered in Estonia (EU), we serve clients across the Baltic region and Eastern Europe — delivering standalone solutions or fully integrated systems combining water chemistry with SCADA automation.

  • Chemical water treatment — IMWTP methodology
  • PLC/SCADA-based boiler room dispatching
  • Remote monitoring via Internet / GSM / GPRS
  • Water analysis, audits, reagent programmes
  • Design, installation, commissioning, maintenance
Why choose us

Our competitive advantages

🔗
01

Integrated approach

Water chemistry + SCADA dispatching in one project — one partner, one contract, seamless integration.

🇪🇺
02

EU company, EU standards

Estonia-registered — full compliance with EN 12952, EN 12953, EU industrial safety directives. VAT-registered, transparent contracting.

03

Payback under 3 months

Dispatching systems pay back in under 3 months through staff optimisation and energy savings exceeding 25%.

🧬
04

IMWTP — proven technology

Systematic, fully documented IMWTP methodology delivering compliant water chemistry on every project.

🛡️
05

24/7 monitoring

Continuous automated monitoring with instant SMS/email alerts. 2-hour response to critical alarms under maintenance contract.

📐
06

End-to-end delivery

From site survey to design, installation, commissioning, training and long-term maintenance — full project lifecycle.

Direction 1 — Chemical Water Treatment

Chemical water treatment technologies

Full-spectrum water chemistry for industrial boilers, steam generators, heating networks, and heat exchangers — based on the IMWTP methodology with automated dosing and online monitoring.

💧

Ion-exchange softening

Removal of Ca²⁺/Mg²⁺ via Na-cation resins. Prevents scale, reduces energy use by up to 25%. Auto-brine regeneration, flows 0.5–100 m³/h.

🧪

Chemical deaeration

Removal of dissolved O₂ and CO₂ using reducing agents — without thermal deaerators. Achieves O₂ <10 µg/L per EN 12952 / EN 12953.

🔬

Corrosion inhibition

Complex inhibitors forming a protective film on metal surfaces. Effective for ferrous and non-ferrous metals.

🌡️

pH correction

Neutralisation of free CO₂ and alkalinity adjustment to pH 8.5–10.5. Prevents acidic corrosion and carbonate scale.

⚗️

Anti-scale treatment

Phosphonate and polymer anti-scalants prevent CaCO₃, CaSO₄, SiO₂ — maintaining year-round heat-transfer efficiency.

📊

IMWTP system

Integrated Modern Water Treatment Process — all stages combined with automated dosing, online monitoring of O₂, pH, conductivity.

Key process

Chemical deaeration technology

Dissolved oxygen is the primary cause of corrosion damage in boiler systems. Chemical deaeration eliminates O₂ and CO₂ without costly thermal equipment.

1

Water analysis

Determination of dissolved O₂, CO₂, pH, hardness, and alkalinity. Basis for reagent selection and dosing rate.

2

Oxygen scavenger dosing

Precise injection of Na₂SO₃, DEHA, or erythorbate. Reduces O₂ to <10 µg/L as required by EN 12952 and EN 12953.

3

CO₂ neutralisation

Free CO₂ neutralised by NaOH, ammonia, or organic amines. Raises pH, eliminates carbonic acid corrosion of condensate pipes.

4

Complex inhibitor dosing

Advantage K350B and similar protect hot-water boilers and heat networks simultaneously against corrosion and scale.

5

Online monitoring & SCADA

Continuous O₂, pH, conductivity measurement with automatic dosing adjustment via PLC and remote alarm notification.

Why chemical deaeration?

No thermal deaerator needed

Eliminates costly thermal columns and vacuum vessels.

Works at any water temperature

Ideal for hot-water boilers where water never reaches 100°C.

Minimal capex

Only a dosing pump + reagent tank. Costs are a fraction of thermal systems.

Backup when deaerators fail

Instantly restores compliant O₂ levels when existing deaerators malfunction.

EN standards compliant

Achieves O₂ <10 µg/L as required by EN 12952 and EN 12953.

Chemical programme

Reagents & applications

ReagentFunctionApplicationType
Na₂SO₃O₂ scavengerSteam boilers, low pressureDeaeration
DEHAO₂ scavenger + film formerMedium/high pressure boilersDeaeration
Erythorbic acidO₂ scavenger (food-safe)Food industry steamDeaeration
NaOH / AmmoniapH correction, CO₂ removalAll boiler and heating systemspH
Advantage K350BComplex inhibitorHot-water boilers, heat networksInhibitor
Amersite 10LO₂ removal, deaerator bypassSteam boilersDeaeration
Boilex E460BWater-chemistry correctionWhen deaerators underperformCorrection
Polyphosphate inhibitorScale prevention + corrosion filmWater supply, heat exchangersInhibitor
Direction 2 — Dispatching & Automation

Dispatching & automation of boiler rooms

Remote monitoring & control — 24/7, any device

We design, supply and commission PLC/SCADA dispatching systems for boiler rooms, heat networks, and water treatment plants — enabling fully automated unattended operation with real-time remote access via Internet, GSM, or GPRS.

>25%
Energy saving via automated heat supply
Productivity increase
<3 mo
Payback via staff optimisation
24/7
Automated monitoring
Equipment — Communication controllers & gateways
FlexHMI Universal Data Gateway — industrial controller for SCADA integration, mounted on DIN rail with ModbusTCP and RS-485 ports
FlexHMI

FlexHMI — Universal Data Gateway

A hardware-software complex with built-in SCADA system for data collection, visualisation and control. Collects data from process automation devices via standard industrial protocols, supports script logic — enabling complex control without a separate PLC.

SCADA built-in MQTT / IoT 2×Ethernet Wi-Fi VPN SMS/Viber/Telegram
View specs →
Neurolink M1 industrial caching gateway — edge data buffering device for SCADA networks with GSM and Ethernet uplinks
Neurolink M1

Neurolink M1 — Industrial Caching Gateway

Industrial caching gateway for Neurolink TCP/RTU protocol. Acts as a standalone server — periodically reads registers from RS-485 devices and caches them, dramatically speeding up data collection in systems with many slow-connection devices.

RS-485 Neurolink TCP Caching server Industrial grade
View specs →
ModbusTCP GPS Tracker with built-in NTP time server — industrial network time synchronisation device
GPS/NTP

ModbusTCP GPS Tracker + NTP Server

Multifunctional device combining GPS tracking of object position and movement in real time with NTP server for precise time synchronisation across all devices on the network. Integrates via ModbusTCP protocol for seamless interaction with automation systems.

GPS tracking NTP server ModbusTCP Ethernet
View specs →
Equipment — Field I/O modules & measurement controllers
Phalaenopsis.Pro Neuron S1 — industrial I/O module with analog and digital channels, ModbusRTU/TCP for SCADA
Neuron S1

Phalaenopsis.Pro Neuron S1 — I/O Module

Industrial distributed I/O module for discrete signal collection, 1Wire temperature sensors and load control. DIN-rail mount (35mm). 8 discrete inputs (with counter function) + 8 relay outputs. 2×Ethernet ports in bridge mode — installs anywhere in existing infrastructure.

8 DI + 8 DO relay 1Wire (32 sensors) 2×Ethernet bridge DIN 35mm 24V power
View specs →
KVEP-16 Measurement and Computing Controller — 16-channel industrial controller for electrode and process monitoring
KVEP-16

KVEP-16 — Measurement & Computing Controller

Based on a modern dual-core processor with 16-channel high-speed ADC. Controls three-phase electrical parameters (current, voltage, power) on both high and low voltage sides in real time. Specifically designed for arc furnace electrode current monitoring and complex power measurements.

16-ch ADC 3-phase measurement Arc furnace LAN
View specs →
Network topology diagram showing Neuron S1 modules chained over ModbusTCP, with router, CCTV, and KVEP-16 controllers

Network topology — Neuron S1 chain

Multiple Neuron S1 modules connect in a chain via their built-in 2-port Ethernet bridge — no additional switches required. The chain connects to a router for upstream network access, and can share infrastructure with CCTV cameras and other devices.

Each module: 2×Ethernet ports (bridge mode), 100 Mbit/s, cable length up to 100m per port.

Real SCADA system examples — from our projects
Three-level system architecture
03

Upper level — Operator workstation (SCADA/HMI)

Dispatcher's PC or web dashboard — graphical mimic diagram, remote parameter adjustment, alarm management, historical archive, automated reporting. Access via Internet, GSM, GPRS, LAN from any device.

02

Middle level — PLC / FlexHMI controller

Collects sensor data, executes control algorithms, manages automatic starts/stops, records alarms in non-volatile memory in real time, transmits data to dispatcher centre.

01

Lower level — Neuron S1, KVEP-16, sensors & actuators

Temperature (1Wire) and pressure sensors (4–20 mA), electromagnetic flow meters, level sensors, gas/CO detectors, leak sensors, motorised valves, VFD pump drives. All signals standardised for PLC integration.

What we automate

Object types & monitoring

From single boiler rooms to multi-site networks — our systems scale to any complexity.

🔥

Gas boiler rooms

♨️

Steam boiler plants

🏭

Industrial boilers

🏗️

Block-modular boilers

🌡️

District heating / ITP

💧

Water treatment plants

⚙️

Pump stations

🔌

Multi-site networks

Control capabilities

  • Remote start/stop of boilers and pumps in normal and emergency modes
  • Automated weather-compensated heat supply regulation
  • Emergency protection shutdown with non-volatile alarm logging
  • Real-time parameter viewing and adjustment from any device
  • Instant SMS / Viber / Telegram alarm notifications

Monitored parameters

  • Supply / return water temperature T1/T2
  • System pressure — supply, return, gas line
  • Water flow rate and thermal energy metering
  • Gas concentration CO / CH₄
  • Water quality: O₂, pH, conductivity, hardness
Scope of supply & implementation

Services & how we deliver

01

Design & engineering

Site survey, TS, PLC/SCADA platform selection, communication channels. Full engineering documentation package.

02

PLC programming & SCADA

Control algorithms, interlocks, protection logic, mimic diagrams, dashboards, alarm lists, trend graphs, automated reports.

03

Installation

Phased installation of sensors, control cabinets and communication equipment in parallel with ongoing works — minimising downtime.

04

Commissioning & testing

Full functional testing of all equipment, PLC logic, SCADA visualisation, alarms and notification systems before handover.

05

Remote communication

Internet (Ethernet/Wi-Fi), GSM/GPRS, MODBUS RTU/TCP, OPC-UA. Secure VPN. SMS/Viber/Telegram alarms. Level2 cloud platform for multi-site.

06

Maintenance & support

Warranty/post-warranty service, remote diagnostics, software updates, staff training. 2-hour critical alarm response under service contract.

1

Survey & specification

Data collection, requirements clarification, TS development and client approval.

2

Design & documentation

Wiring diagrams, PLC program, SCADA screens, cabinet layout. Engineering package to client before installation.

3

Phased installation

Sensors, control cabinets, communication equipment installed in parallel — minimising downtime.

4

Commissioning & testing

Full test of all logic, channels and alarms. Protection verified. Alarm notifications tested to duty personnel.

5

Handover & training

Commissioning act + full technical documentation. Staff training on system use and emergency procedures.

Integration & platforms

Communication protocols

MODBUS RTU/TCP, OPC-UA, BACnet, M-Bus, PROFIBUS, RS-485/232, Neurolink TCP

Own hardware

FlexHMI, Neuron S1, Neurolink M1, KVEP-16, GPS/NTP tracker

SCADA / HMI

Built-in FlexHMI SCADA, WinCC, Ignition, TRACE MODE, ASMD 1.5.1, Grafana, Node-RED

Remote access

Internet, GSM/GPRS, VPN, Level2 cloud — multi-site management from one dispatcher centre.

Notifications

SMS · Viber · Telegram · Email

Ready to start?

One partner — water treatment & dispatching

Request a free consultation. We assess your facility and propose an integrated solution combining chemical water treatment with automated SCADA dispatching.

Request free consultation
Get in touch

Contact us

Our team is ready to assess your water treatment and dispatching challenges and propose the most effective solution for your facility.

📍
Address
J. Koorti tn 2-33, 13623
Tallinn, Harju, Estonia
🏢
Registry / VAT

17122902 / EE102900668